Physiology of Perfusion

Four Most Important Equations

 

 

Interactions Article (Part I, Part II)

 

Nunn Resp Physiology

the effects of deadspace on CO2 are ameliorated by an increase in minute volume, unless pt can't spont breathe

~35-40% fiO2 will eliminate deadspace effects on O2

Alveolar deadspace in our patients is often caused by decreased lung perfusion

at decreased temperatures, CO2 becomes more soluble

 

Alveolar Ventilation for Oxygenation

Figure 17-24 For any given O2 concentration in inspired gas, the relationship between alveolar ventilation and Pao2 is hyperbolic. As the inspired O 2 concentration is increased, the amount that alveolar ventilation must decrease to produce hypoxemia is greatly increased. BTPS, body temperature, ambient pressure, saturated. (Redrawn from Lumb AB: Respiratory system resistance: Measurement of closing capacity. In Lumb AB [ed]: Nunn's Applied Respiratory Physiology, 5th ed. London, Butterworths, 2000, p 79.) (From Miller's Anesthesia)

 

Apneic Oxygenation (Anesthesiology 1959;Nov/Dec:789)

 

Desaturation Time with Preox and Occluded Airway

 

Simulator of the effect of supp. oxygen on detecting hypoventilation

 

Deadspace

Mask adds 82 cc of deadspace compared to tube, even though it is actually 125 cc more space (BR J Anesth 1969;41:94)

What determines Venous Saturation


Alveolar Ventilation for CO2

J Clin Anesth. 1989;1(5):328-32. Links
Comment in:
J Clin Anesth. 1989;1(5):323-7.
J Clin Anesth. 1991 Jan-Feb;3(1):82-4.
The PaCO2 rate of rise in anesthetized patients with airway obstruction.
Stock MC, Schisler JQ, McSweeney TD.
Department of Anesthesiology, Emory University School of Medicine, Atlanta, GA.
Apneic, anesthetized patients frequently develop airway obstruction or may be disconnected from ventilatory support. The rate of PaCO2 rise is usually assumed to be equal to that of anesthetized humans who are receiving apneic oxygenation. Apneic oxygenation may eliminate CO2 because it requires a continuous O2 flow. The CO2 rate of rise in anesthetized humans with airway obstruction was measured. Fourteen consenting healthy adults were monitored continuously with pulse oximetry and EKG. Enflurane--O2 anesthesia was established for at least 10 minutes with normal PaCO2 without neuromuscular blockade so that anesthesia was deep enough to prevent spontaneous ventilation. Then, patients' tracheal tubes were clamped. Arterial blood samples were obtained before and after 0, 20, 40, 60, 120, 180, 240, and 300 seconds after clamping, provided that oxyhemoglobin saturation exceeded 0.92. The equation that best described the PaCO2 rise was a logarithmic function. Piecewise linear approximation yielded a PaCO2 increase of 12 mmHg during the first minute of apnea, and 3.4 mmHg/minute thereafter. These values should be employed when estimating the duration of apnea from PaCO2 change for anesthetized patients who lack ventilatory support. In addition, it appears that the flows of O2 that most earlier investigators used when delivering apneic oxygenation probably did not eliminate significant CO2 quantities.

 

 

PaCO2=VCO2 (production) / (VE x (1- Vd/Vt)

VE=minute ventilation Vd=deadspace Vt=tidal volume

 

Bohr Equation Vd/Vt=(PaCO2-PetCO2)/PaCO2

Normal=0.2-0.4

 

 

Spontaneous breathing patients will breathe at a PaCO2 of 50; with preoxygenation, it is a PaCO2 of 60

 

In an apneic anesthetized patient the rate of CO2 rise

12 mmHg in the 1st minute

3.5 mmHg per minute thereafter

(Anesthesiology 1961;22:419, J Clin Anesth 1989;1:328)

 

Hypercapnea

VT=VA+VD (Alveolar/Deadspace)

PaCO2=PACO2 in normal lungs

 

Increased CO2 production (hypermetabolic states)

Decreased Alveolar ventilation/Increased deadspace ventilation

Decreased Tidal Volume

 

 

Aa Gradient

8+Age/5 is normal

Hypoxemia

Type I-hypoxemic, PaO2<60

Type II-hypercapneic w/wo hypoxemia, PaCO2>50

 

Mechanisms of Hypoxemia

  1. Inadequate PAO2

  2. V/Q Mismatch

  3. Shunt (Will not improve with O2)

  4. Diffusion Abnormality

  5. Low SvO2

PAO2=FiO2(PB-PH2O) - PaCO2/R

R=.8

 

 

Reabsorbtion atelectasis and loss of hypoxic pulmonary vasoconstriction may actually cause hypoxemia to get worse in the presence of high fiO2 and shunt.

 

article on the mechanisms of hypoxemia (intensive care medicine 2005;31:1017-1019)

 

 

 

Decreased PaO2 can actually lower respiratory drive in the critically ill, studies done in patients with cardiogenic shock.

Primary neurologic problems can result in decreased respiratory drive.  these include AML, spinal cord injuries, guillain-barre, and muscular disorders.

Respiratory muscle fatigue from COPD/Asthma, ARDS, etc.

 

Increased production in sepsis, hypothermia, salicilates,

Increased deadspace ventilation

Hypercapnia can decrease respiratory drive.

 

 

West Zones

Hemoglobin Saturation Curve

shift to the right is right (good) i.e. more O2 released to cells

 

 

Oxygen Transport

the first equation you need is the

Oxygen carrying capacity of blood

CaO2=(Hb) x 1.38 x SaO2 + (0.003 x PaO2)

1.38 is the carrying capacity of a gram of Hb

 

normally 17-20 cc/dL

 

Note that >99% of the capacity is from Hb binding

 

Oxygen Delivery to Tissues

DO2=CaO2 cc/dL x (CO L/min) x 10

 

10 is the conversion factor to convert L to dL

normally 950-1150 cc/min

 

DO2I=CaO2 x CI x 10

normally 550-650 cc/min/m2 

 

Oxygen Consumption by Tissues

Fick Equation

VO2=(CaO2-CvO2) x CO x 10    or

VO2=1.38 (Hb)(CO)(SaO2-SvO2)/10

normally 240-290 cc/min

 

 

VO2=oxygen consumed

DO2=Oxygen delivered

 

VO2/DO2 is normally 0.22-0.27 (0.25)

Rising VO2/DO2 ratio is a sign of inadequate tissue oxygenation

 

 

CvO2=(Hb) x 1.34 x SvO2 + 0.003 x PvO2

Normally 15 cc/dl

 

 

VO2I=(CaO2-CvO2) x CI x 10

Normally 115-165 cc/min/m2 

 

PvO2 of 28 is required to cause oxygen to diffuse into cells, below this point anaerobic metabolism occurs. This is equivalent to an SvO2 of 50% unless the oxyhemoglobin curve is shifted.

 

vasoregulation is an important factor that can not be measured.

 

Cirrhosis and sepsis look hemodynamically identical

 

capillary shunt

blood flowing past unventilated alveoli

atelectasis

pneumonia

ards

pulmonary edema

 

anatomic shunt

positive pressure may worsen

 

 

overventilation compresses blood vessels leading to increasing shunt and increasing deadspace

 

 

 

Ve=minute volume

Ve=Vd + Va

 

 

we compensate by increasing CO and increasing oxygen extraction

we can decrease extraction ratio to get venous sat of 40%

we can easily triple CO or up to 20 L/min

 

 

 

 

 

Is oxygen delivery adequate for the patient's needs?

Measured

PaO2

PaCO2

SaO2 or SpO2

SvO2 (Mixed Venous)

Venous Oxygen Tension PvO2

Hb

CO

 

Calculated

Pulmonary Capillary O2 Content (CcO2)

Arterial Oxygen Content (CaO2)

Venous Oxygen Conent (CvO2)

Arterial-venous oxygen content difference (Ca-vO2)

Oxygen utilization coefficient (OUC)

Oxygen Delivery Index (DO2I)

Oxygen Consumption Index (VO2I)

Intrapulmonary Shunt (Qsp/Qt)

Cardiac Index (CI)

 

Oxygen content=oxygen bound to Hb + oxygen dissolved in plasma

Oxygen bound=Hgb concentration x (1.34 cc oxygen per g Hb) x saturation of Hb

Oxygen dissolved=blood oxygen tension x (0.0031 solubility coefficient of oxygen in blood)

 

 

CcO2 = pulmonary end-capillary oxygen content

= oxygen bound to Hgb as it leaves the alveolus

= (1.34 x Hgb x 1.0) + (PAO2 x 0.0031)

The saturation of oxygen in the pulmonary end-capillary should be 1.0 if FiO2 > 0.21 PAO2 = alveolar oxygen tension = FiO2 x [(PB-PH20)-(PaCO2/RQ)] PB = barometric pressure, PH2O = water vapor pressure, RQ = respiratory quotient = 0.40 x [(760 torr - 47 torr) - (40 torr/0.8) (assuming normal values) = 0.40 x 663 torr = 265 torr PAO2 can also be approximated rapidly at the bedside as 700 torr x FiO2 - 50 torr = 20.1 ml O2/dl blood + 0.8 ml O2/dl blood (assuming normal values) = 20.9 ml O2/dl blood

 

CaO2 = arterial oxygen content = arterial oxygen content as blood leaves the heart = oxygen bound to Hgb in arterial blood (98 %) + oxygen dissolved in arterial plasma (2%) = (1.34 x Hgb x SaO2) + (PaO2 x 0.0031) 1.34 mL of oxygen can be carried on each gram of human hemoglobin; this number varies from species to species = (1.34 x 15 g x 1.0) + (100 torr x 0.0031) (assuming normal values) = 20.1 ml O2/dl blood + 0.31 ml O2/dl blood = 20.4 ml O2/dl blood

 

CvO2 = venous oxygen content = venous oxygen content as blood returns to the heart = oxygen bound to Hgb in venous blood (>99%) + oxygen dissolved in venous plasma (<1%) = (1.34 x Hgb x SvO2) + (PvO2 x 0.0031) PvO2 can be measured with a venous blood gas, or estimated as 35 torr with high accuracy = (1.34 x 15 g x 0.75) + (35 torr x 0.0031) (assuming normal mixed venous oxygen saturations) = 15.1 ml O2/dl blood + 0.11 ml O2/dl blood = 15.2 ml O2/dl blood

 

Ca-vO2 = arterial-venous oxygen content difference = CaO2 - CvO2 = 20.4 ml O2/dl blood - 15.2 ml O2/dl blood = 5.2 ml O2/dl blood

 

Once the oxygen contents throughout the vascular circuit have been calculated, the amount of oxygen delivered to the tissues (oxygen delivery index or DO2I) and the amount of oxygen consumed by the tissues (oxygen consumption index or VO2I) can be calculated. DO2I = oxygen delivery index = volume of gaseous O2 pumped from the left ventricle per minute per meter squared BSA = CI x CaO2 x 10 dL/L (the 10 dL/L corrects for the fact that CI is measured in L/min/m2 and oxygen content is measured in ml/dl) = ~600 ml O2/min.m2 VO2I = oxygen consumption index = volume of gaseous O2 consumed by the body per minute per meter squared BSA = volume of oxygen leaving the heart - volume of oxygen returning to the heart = [(CI x CaO2) - (CI x CvO2)] x 10dL/L = CI x Ca-vO2 x 10 dL/L = ~150 ml O2/min.m2 Two oxygenation parameters characterize the relative balance between oxygen delivery and oxygen consumption (“supply versus demand”): the oxygen utilization coefficient (OUC) and the mixed venous oxygen saturation (SvO2). The OUC, also known as the oxygen extraction ratio or O2ER, is the percentage of delivered oxygen which is consumed by the body and is calculated as follows: OUC = Oxygen utilization coefficient = VO2I / DO2I = ~0.25 If the SaO2 is maintained at a relatively high level (> 0.92), the OUC can be approximated as:
= 1- SvO2

 

 

MIXED VENOUS OXIMETRY The SvO2, by providing a continuous “online” indication of the relative balance between VO2I and DO2I, can be used:

1) as an "early warning signal" to detect the onset of oxygen transport imbalance before clinical deterioration occurs

2) to evaluate the efficacy of therapeutic interventions such that physiologic end-points are reached more quickly

3) to identify potentially detrimental consequences of “patient care” (suctioning, positioning, etc.) that might otherwise go unnoticed It is essential to remember that the SvO2 is a "flow-weighted average" of the venous saturations from all perfused vascular beds. Thus, the SvO2 does not reflect the oxygen transport adequacy of non-perfused vascular beds nor does a “normal” SvO2 mean that all tissues are adequately oxygenated. It is only an average estimate of venous saturation for the whole body. It provides an impression of the overall balance between VO2I and DO2I, but does not yield information about the adequacy of perfusion of any individual vascular bed. If the SvO2 falls, VO2I is increasing (and may lead to anaerobic metabolism if DO2I is not sufficient) or DO2I is decreasing. If the SvO2 increases, VO2I is decreasing, DO2I is increasing, blood is being shunted pass vascular beds without releasing its oxygen (such as in sepsis or cirrhosis), or oxygen uptake by the tissues is decreased. There are four determinants of SvO2: Hgb, cardiac output, SaO2, and VO2I.

 

There are thus four main causes of low SvO2:

1) anemia,

2) low cardiac output,

3) arterial desaturation

4) increased VO2I.

 

In the presence of low SvO2, changes in these four parameters should be investigated. There are two common sources of error in venous oximetry measurements. The use of continuous venous oximetry relies on reflectance spectrophotometry technology. If the catheter is not properly calibrated via either an in vitro calibration prior to catheter insertion or an in vivo calibration via a mixed venous blood gas, the SvO2 values obtained may not accurately reflect the true oxygen transport balance. Careful attention should be given to catheter calibration to prevent such errors. The second source of error is catheter malposition. If the catheter tip is against the wall of the pulmonary artery, the light reflected back to the catheter will be amplified artificially increasing the SvO2 measurement. Proper catheter positioning is essential to obtaining reliable SvO2 values. Thus, SvO2, although not a specific indicator of the cause of hemodynamic and oxygen transport compromise, is a sensitive “online” monitor of the adequacy of balance between oxygen delivery and oxygen consumption accurately predicting potentially detrimental changes in patient status before they become clinically apparent. This allows appropriate therapeutic interventions to be initiated prior to the development of severe changes in a patient’s cardiorespiratory status.

 

FUNDAMENTAL QUESTIONS TO BE ANSWERED IN EVALUATING OXYGEN TRANSPORT

1) Is DO2I adequate for the patient's needs?

• DO2I should be at least 10mL/kg/min

• If inadequate, check the OUC; it should not exceed 0.35 as this suggests that oxygen supply is barely meeting oxygen demand

• Remember that SvO2 ≅ 1-OUC (for SaO2 > 0.92); this can be used as a rough approximation in assessing the adequacy of oxygen transport balance

• Ensure that the patient’s hemoglobin is appropriate for their degree of shock; consider transfusion of packed red blood cells if DO2I is inadequate When oxygen delivery (DO2I) exceeds oxygen demand, oxygen consumption will “plateau” and will no longer rise as oxygen delivery increases (Figure 3). This balance where DO2I meets the cellular needs of the body should be the goal in critical care. At the point where DO2I no longer meets oxygen demand (the so called “critical DO2”), oxygen consumption becomes “supply dependent”.

 

In this region of supply dependency, increases in DO2I result in increases in VO2I indicating that the body’s oxygen demands were not previously being met. DO2IVO2I"Supply Dependency""Critical DO2" Figure 3:

Oxygen Supply Dependency One of the most important determinants of tissue oxygen delivery is the arterial hemoglobin concentration. While oxygen delivery from the left ventricle is linearly related to the hemoglobin concentration, capillary flow may be impaired at extremely high hematocrits. The optimal hemoglobin concentration to maximize tissue oxygen delivery seems to be in the range of between 10 and 13 grams per deciliter. Whether or not transfusion to achieve these high hemoglobin levels improves outcome remains to be proven. Since loading oxygen on to the hemoglobin molecules is rarely a significant problem, attention must be turned to factors which will help unload oxygen from the hemoglobin at the tissue level. Judicious amounts of acidemia, hypercarbia, and fever all produce a right shift in the oxyhemoglobin association curve and may improve tissue unloading of oxygen (Figure 4). Figure 4: Oxyhemoglobin Dissociation Curve

2) Is cardiac output adequate for oxygen consumption?

• Check the Ca-vO2 􀂾 If < 5 ml O2/dl blood, then cardiac output is sufficient to meet the body's demands for oxygen. 􀂾 If > 5 ml O2/dl blood, the body is extracting an abnormally high percentage of oxygen from the blood as it passes through the tissues and attempts to increase cardiac output (and therefore DO2I) should be undertaken.

• Check the heart rate and stroke volume 􀂾 Cardiac output is equal to the sum of all of the stroke volumes produced each minute. Very high heart rates may reduce diastolic time and ventricular filling, thereby impairing stroke volume. While the optimal heart rate is unknown, heart rates < 80 or > 120 beats per minute are probably not optimal in critically ill adult patients. Patients with such high heart rates may benefit from fluid resuscitation, beta-blockade, or correction of abnormal cardiac rhythms (such as atrial fibrillation) that can reduce diastolic filling time. Stroke volume should also be optimized through fluid resuscitation.

 

3) Is oxygen consumption adequate for demand?

• Check a lactic acid level 􀂾 If > 2.5 mmol/L, lactic acid is being produced secondary to anaerobic metabolism (an imbalance between oxygen supply and demand) and attempts to increase cardiac output and DO2I should be undertaken. 􀂾 If the lactic acid level is high and SvO2 is normal, the elevation in lactic acid is probably due to a previous episode of anaerobic metabolism and oxygen debt.
6 Revised 7/9/02
􀂾 If the lactic acid level is high and SvO2 is low, anaerobic metabolism is likely still occurring and must be treated aggressively.

 

4) Is the patient's hypoxemia due to a pulmonary problem (i.e., increased intrapulmonary shunt) OR to a low flow state (i.e., low Ca-vO2)?

• Calculate the patient's intrapulmonary shunt (Qsp/Qt) INTRAPULMONARY SHUNT “Intrapulmonary shunt" (or "venous admixture") refers to blood which does not pass through ventilated portions of the lung and leaves the lungs desaturated resulting in a depressed PaO2.

 

In the normal lung, there are three potential sources of shunt:

1) bronchial artery blood which enters the pulmonary veins after giving up some of its oxygen to the bronchi

2) desaturated blood which enters the left ventricle via the Thebesian veins after perfusing the myocardium

3) normal alveolar collapse in the apices of the lungs (West’s Zone I lung)

 

Normal intrapulmonary shunt is 2-5%. It may exceed 50% in patients with severe acute respiratory distress syndrome (ARDS).

Intrapulmonary shunt is an example of an "oxygen refractory" hypoxia: the shunted blood is not exposed to ventilated alveoli and cannot be saturated with oxygen regardless of the oxygen fraction administered.

 

It is calculated automatically by the bedside monitors. The ventilation-perfusion index or “VQI” on the Edwards Explorer and Vigilance monitors is an “online” approximation of Qsp/Qt which provides a minute-to-minute estimate of the degree of intrapulmonary shunt. The derivation of the shunt equation is included below.

Qt = total cardiac output Qs = shunted portion of cardiac output Qns = normal pulmonary end-capillary blood flow that is not shunted past abnormal alveoli

Qt = Qs + Qns or Qns = Qt - Qs Qt (CaO2) = total oxygen delivered to the body (DO2) Qs (CvO2) = oxygen content of shunted blood Qns (CcO2) = oxygen content of end-capillary blood Therefore, [Total oxygen delivered equals the sum of oxygen in both shunted and non-shunted blood] Qt (CaO2) = Qs (CvO2) + Qns (CcO2) Qt (CaO2) = Qs (CvO2) + (Qt - Qs)(CcO2) [Substituting (Qt - Qs) for Qns] Qt (CaO2) = Qs (CvO2) + Qt (CcO2) - Qs (CcO2) Qs (CcO2 - CvO2) = Qt (CcO2 - CaO2) Qs/Qt = CcO2 - CaO2 [The intrapulmonary shunt equation] CcO2 - CvO2

 

Microcirculation

(Curr Opin Crit Care 2005;11:240)

Vasodilators in Septic Shock (Inten Care Med 2002;28:1208)

vessels <300 um

 

Central Venous-Arterial CO2 difference can be used to calculate cardiac index (Inten Care Med 2005;31:818)

 

CO can also be calculated with glucose clearance (inten care med 2004;30:2067)

 

Occult hypoperfusion, as evidenced by increased lactate, is associated with increased mortality in hemodynamically stable surg patients (Crit Care 2004;8(2):R60)

 

Venous Return

arteries and veins are compliant with downstream resistive elements

veins are collapsible when right atrial pressure is less than zero

venous return regulates cardiac output

 

Compensation for Anemia

 

 

shunt causes hypercapnea and by measurement, an increase in physiological deadspace

you don't really see an increase in co2 until shunt % greater than 30

 

PEEP

IPAP causes benefits of NIV in asthma, EPAP is the worst (Crit Care 2004;8(2):R72)

 

CPAP is better for dynamics than EPAP (Anesth 1981;55:416)

 

 